{"_buckets": {"deposit": "05bf5a68-2ac4-449f-bbe2-d85c5e5494ec"}, "_deposit": {"created_by": 1, "id": "24762", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "24762"}, "status": "published"}, "_oai": {"id": "oai:kumadai.repo.nii.ac.jp:00024762", "sets": ["443"]}, "author_link": ["146914", "111331", "111317", "111313", "111329", "111311", "111325", "111316", "111314", "111328", "111315", "111330", "111327"], "item_16_alternative_title_22": {"attribute_name": "その他の言語のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Combinations of Scan Parameters and Image Quality at C-arm CT for Abdominal Imaging"}]}, "item_16_alternative_title_23": {"attribute_name": "タイトル(ヨミ)", "attribute_value_mlt": [{"subitem_alternative_title": "フクブ リョウイキ ノ C-arm CT ニ オケル スキャン パラメータ ト ガシツ"}]}, "item_16_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-07-14", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "772", "bibliographicPageStart": "765", "bibliographicVolumeNumber": "65", "bibliographic_titles": [{"bibliographic_title": "日本放射線技術学会雑誌"}]}]}, "item_16_creator_3": {"attribute_name": "別言語の著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nagasue, Nozomu"}], "nameIdentifiers": [{"nameIdentifier": "111325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Funama, Yoshinori"}], "nameIdentifiers": [{"nameIdentifier": "146914", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Oniki, Rika"}], "nameIdentifiers": [{"nameIdentifier": "111327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Segawa, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "111328", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwatake, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "111329", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawachino, Tomohiko"}], "nameIdentifiers": [{"nameIdentifier": "111330", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uetani, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "111331", "nameIdentifierScheme": "WEKO"}]}]}, "item_16_description_17": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_16_description_46": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_16_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "We measured the contrast-to-noise ratio (CNR) and evaluated low-contrast images and streak artifacts to optimize abdominal C-arm CT imaging, and we investigated the view number, acquisition matrix, and pixel depth. To measure CNR, we filled 0.125–1.0-inch cavities in an American Association of Physicists in Medicine (AAPM) CT performance phantom with a sodium chloride solution. Five radiological technologists visually evaluated the noise, signal conspicuity at low-and high-signal density, and the overall image quality using paired comparisons based on Thurstone’s law. In a given acquisition matrix, the total view number had the greatest effect on the image noise, artifacts, and signal detectability on C-arm CT images. For a given incident dose per view on the flat-panel detector (FPD), fewer images with noise and streak artifacts resulted when a larger view number was selected.", "subitem_description_type": "Other"}]}, "item_16_description_77": {"attribute_name": "URL", "attribute_value_mlt": [{"subitem_description": "http://www.jstage.jst.go.jp/article/jjrt/65/6/65_765/_article/-char/ja/", "subitem_description_type": "Other"}]}, "item_16_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "公益社団法人 日本放射線技術学会"}]}, "item_16_relation_16": {"attribute_name": "情報源(ISSN)", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "03694305"}]}]}, "item_16_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "(c) 2009 Japanese Society of Radiological Technology"}]}, "item_16_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00197784", "subitem_source_identifier_type": "NCID"}]}, "item_16_subject_20": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "492.4", "subitem_subject_scheme": "NDC"}]}, "item_16_text_18": {"attribute_name": "形態", "attribute_value_mlt": [{"subitem_text_value": "1898899 bytes"}]}, "item_16_text_38": {"attribute_name": "別言語の出版者", "attribute_value_mlt": [{"subitem_text_value": "Japanese Society of Radiological Technology"}]}, "item_16_text_47": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "雑誌掲載論文"}]}, "item_16_text_48": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Journal Article"}]}, "item_16_text_49": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_16_text_50": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "01"}]}, "item_16_text_76": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/2298/19360"}]}, "item_16_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "永末, 望"}], "nameIdentifiers": [{"nameIdentifier": "111311", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "船間, 芳憲"}, {"creatorName": "フナマ, ヨシノリ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "146914", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鬼木, 里佳"}], "nameIdentifiers": [{"nameIdentifier": "111313", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "瀬川, 敦史"}], "nameIdentifiers": [{"nameIdentifier": "111314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩竹, 聡"}], "nameIdentifiers": [{"nameIdentifier": "111315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川内野, 友彦"}], "nameIdentifiers": [{"nameIdentifier": "111316", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上谷, 雅孝"}], "nameIdentifiers": [{"nameIdentifier": "111317", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-03-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "65_765.pdf", "filesize": [{"value": "1.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1900000.0, "url": {"label": "65_765.pdf", "url": "https://kumadai.repo.nii.ac.jp/record/24762/files/65_765.pdf"}, "version_id": "d6e664ca-1ad3-42f0-b2ad-084191e09a83"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "C-arm CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "scan protocol", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image quality", "subitem_subject_scheme": "Other"}, {"subitem_subject": "radiation dose", "subitem_subject_scheme": "Other"}, {"subitem_subject": "abdominal imaging", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "腹部領域のC-arm CTにおけるスキャンパラメータと画質", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "腹部領域のC-arm CTにおけるスキャンパラメータと画質"}]}, "item_type_id": "16", "owner": "1", "path": ["443"], "permalink_uri": "http://hdl.handle.net/2298/19360", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-06-07"}, "publish_date": "2011-06-07", "publish_status": "0", "recid": "24762", "relation": {}, "relation_version_is_last": true, "title": ["腹部領域のC-arm CTにおけるスキャンパラメータと画質"], "weko_shared_id": 1}
腹部領域のC-arm CTにおけるスキャンパラメータと画質
http://hdl.handle.net/2298/19360
http://hdl.handle.net/2298/193604bc394df-6e10-44d3-a631-0f1f17a2d5f7
名前 / ファイル | ライセンス | アクション |
---|---|---|
65_765.pdf (1.9 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-06-07 | |||||
タイトル | ||||||
タイトル | 腹部領域のC-arm CTにおけるスキャンパラメータと画質 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | C-arm CT, scan protocol, image quality, radiation dose, abdominal imaging | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
著者 |
永末, 望
× 永末, 望× 船間, 芳憲× 鬼木, 里佳× 瀬川, 敦史× 岩竹, 聡× 川内野, 友彦× 上谷, 雅孝 |
|||||
別言語の著者 |
Nagasue, Nozomu
× Nagasue, Nozomu× Funama, Yoshinori× Oniki, Rika× Segawa, Atsushi× Iwatake, Satoshi× Kawachino, Tomohiko× Uetani, Masataka |
|||||
内容記述 | ||||||
内容記述 | We measured the contrast-to-noise ratio (CNR) and evaluated low-contrast images and streak artifacts to optimize abdominal C-arm CT imaging, and we investigated the view number, acquisition matrix, and pixel depth. To measure CNR, we filled 0.125–1.0-inch cavities in an American Association of Physicists in Medicine (AAPM) CT performance phantom with a sodium chloride solution. Five radiological technologists visually evaluated the noise, signal conspicuity at low-and high-signal density, and the overall image quality using paired comparisons based on Thurstone’s law. In a given acquisition matrix, the total view number had the greatest effect on the image noise, artifacts, and signal detectability on C-arm CT images. For a given incident dose per view on the flat-panel detector (FPD), fewer images with noise and streak artifacts resulted when a larger view number was selected. | |||||
書誌情報 |
日本放射線技術学会雑誌 巻 65, 号 6, p. 765-772, 発行年 2009-07-14 |
|||||
書誌レコードID | ||||||
収録物識別子 | AN00197784 | |||||
権利 | ||||||
権利情報 | (c) 2009 Japanese Society of Radiological Technology | |||||
情報源(ISSN) | ||||||
関連名称 | 03694305 | |||||
フォーマット | ||||||
内容記述 | application/pdf | |||||
形態 | ||||||
1898899 bytes | ||||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
日本十進分類法 | ||||||
主題 | 492.4 | |||||
その他の言語のタイトル | ||||||
その他のタイトル | Combinations of Scan Parameters and Image Quality at C-arm CT for Abdominal Imaging | |||||
タイトル(ヨミ) | ||||||
その他のタイトル | フクブ リョウイキ ノ C-arm CT ニ オケル スキャン パラメータ ト ガシツ | |||||
出版者 | ||||||
出版者 | 公益社団法人 日本放射線技術学会 | |||||
別言語の出版者 | ||||||
Japanese Society of Radiological Technology | ||||||
資源タイプ | ||||||
内容記述 | 論文(Article) | |||||
資源タイプ・ローカル | ||||||
雑誌掲載論文 | ||||||
資源タイプ・NII | ||||||
Journal Article | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
01 | ||||||
URL | ||||||
内容記述 | http://www.jstage.jst.go.jp/article/jjrt/65/6/65_765/_article/-char/ja/ |