{"_buckets": {"deposit": "f92a0758-f5fd-4497-9240-61f4a14ceb8b"}, "_deposit": {"created_by": 1, "id": "29191", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "29191"}, "status": "published"}, "_oai": {"id": "oai:kumadai.repo.nii.ac.jp:00029191", "sets": ["443"]}, "author_link": ["134261"], "item_16_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "206", "bibliographicPageStart": "199", "bibliographicVolumeNumber": "5", "bibliographic_titles": [{"bibliographic_title": "Radiological Physics and Technology"}]}]}, "item_16_creator_3": {"attribute_name": "別言語の著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "荒木, 不次男", "creatorNameLang": "ja"}, {"creatorName": "アラキ, フジオ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Araki, Fujio", "creatorNameLang": "en"}], "familyNames": [{"familyName": "荒木", "familyNameLang": "ja"}, {"familyName": "アラキ", "familyNameLang": "ja-Kana"}, {"familyName": "Araki", "familyNameLang": "en"}], "givenNames": [{"givenName": "不次男", "givenNameLang": "ja"}, {"givenName": "フジオ", "givenNameLang": "ja-Kana"}, {"givenName": "Fujio", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "134261", "nameIdentifierScheme": "WEKO"}]}]}, "item_16_description_17": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_16_description_46": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_16_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "The purpose of this study was to calculate the replacement correction factor, P_\u003crepl\u003e (the product P_\u003cgr\u003eP_\u003cfl\u003e in the AAPM\u0027s notation, or the product p_\u003ccav\u003ep_\u003cdis\u003e in the IAEA’s notation), at a reference depth, d_\u003cref\u003e, for cylindrical chamber cavities in clinical photon and electron beams by Monte Carlo simulation. P_\u003crepl\u003e was calculated for cavities with a combination of various diameters and lengths. P_\u003crepl\u003e values calculated in photon and electron beams were typically higher than those recommended by the TG-51 and TRS-398 dosimetry protocols. P_\u003crepl\u003e values for a Farmer chamber cavity were higher by 0.3 to 0.2% and by 0.7 to 0.4%, respectively, than data of TG-51 and TRS-398, at photon energies of ^\u003c60\u003eCo to 18 MV. Similarly, the P_\u003crepl\u003e values for electron beams were higher by 1.5 to 1.1% than data for both protocols, in a range of 6-18 MeV. The P_\u003crepl\u003e values depended upon the cavity diameter and length, especially for lower electron energies. We found that P_\u003crepl\u003e values of cylindrical chamber cavities for photon and electron beams were significantly different from those recommended by TG-51 and TRS-398.", "subitem_description_type": "Other"}]}, "item_16_description_77": {"attribute_name": "URL", "attribute_value_mlt": [{"subitem_description": "http://link.springer.com/article/10.1007%2Fs12194-012-0154-5", "subitem_description_type": "Other"}]}, "item_16_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Japan"}]}, "item_16_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s12194-012-0154-5", "subitem_relation_type_select": "DOI"}}]}, "item_16_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18650333", "subitem_source_identifier_type": "ISSN"}]}, "item_16_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12236881", "subitem_source_identifier_type": "NCID"}]}, "item_16_subject_20": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "492.8", "subitem_subject_scheme": "NDC"}]}, "item_16_text_18": {"attribute_name": "形態", "attribute_value_mlt": [{"subitem_text_value": "323921 bytes"}]}, "item_16_text_47": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "雑誌掲載論文"}]}, "item_16_text_48": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Journal Article"}]}, "item_16_text_49": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_16_text_50": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "01"}]}, "item_16_text_76": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/2298/33042"}]}, "item_16_text_78": {"attribute_name": "コメント", "attribute_value_mlt": [{"subitem_text_value": "The final publication is available at Springer via http://dx.doi.org/10.1007/s12194-012-0154-5 "}, {"subitem_text_value": "【著者所属】 熊本大学大学院生命科学研究部 医用画像学"}]}, "item_16_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "荒木, 不次男", "creatorNameLang": "ja"}, {"creatorName": "アラキ, フジオ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Araki, Fujio", "creatorNameLang": "en"}], "familyNames": [{"familyName": "荒木", "familyNameLang": "ja"}, {"familyName": "アラキ", "familyNameLang": "ja-Kana"}, {"familyName": "Araki", "familyNameLang": "en"}], "givenNames": [{"givenName": "不次男", "givenNameLang": "ja"}, {"givenName": "フジオ", "givenNameLang": "ja-Kana"}, {"givenName": "Fujio", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "134261", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-03-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Radiol Phys Technol_5_2_199–206.pdf", "filesize": [{"value": "323.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 323900.0, "url": {"label": "Radiol Phys Technol_5_2_199–206.pdf", "url": "https://kumadai.repo.nii.ac.jp/record/29191/files/Radiol Phys Technol_5_2_199–206.pdf"}, "version_id": "15534a34-1d49-40ea-bb97-643ce10ff2ce"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Replacement correction factor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Cylindrical ion chamber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Clinical dosimetry protocols", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Monte Carlo calculations", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Monte Carlo calculations of the replacement correction factor, Ρ_\u003crepl\u003e, for cylindrical chamber cavities in clinical photon and electron beams", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Monte Carlo calculations of the replacement correction factor, Ρ_\u003crepl\u003e, for cylindrical chamber cavities in clinical photon and electron beams"}]}, "item_type_id": "16", "owner": "1", "path": ["443"], "permalink_uri": "http://hdl.handle.net/2298/33042", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-09-16"}, "publish_date": "2015-09-16", "publish_status": "0", "recid": "29191", "relation": {}, "relation_version_is_last": true, "title": ["Monte Carlo calculations of the replacement correction factor, Ρ_\u003crepl\u003e, for cylindrical chamber cavities in clinical photon and electron beams"], "weko_shared_id": -1}
Monte Carlo calculations of the replacement correction factor, Ρ_<repl>, for cylindrical chamber cavities in clinical photon and electron beams
http://hdl.handle.net/2298/33042
http://hdl.handle.net/2298/3304295848158-82ea-425a-b3f1-29cba61869af
名前 / ファイル | ライセンス | アクション |
---|---|---|
Radiol Phys Technol_5_2_199–206.pdf (323.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-09-16 | |||||
タイトル | ||||||
タイトル | Monte Carlo calculations of the replacement correction factor, Ρ_<repl>, for cylindrical chamber cavities in clinical photon and electron beams | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題 | Replacement correction factor, Cylindrical ion chamber, Clinical dosimetry protocols, Monte Carlo calculations | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
著者 |
荒木, 不次男
× 荒木, 不次男 |
|||||
別言語の著者 |
荒木, 不次男
× 荒木, 不次男 |
|||||
内容記述 | ||||||
内容記述 | The purpose of this study was to calculate the replacement correction factor, P_<repl> (the product P_<gr>P_<fl> in the AAPM's notation, or the product p_<cav>p_<dis> in the IAEA’s notation), at a reference depth, d_<ref>, for cylindrical chamber cavities in clinical photon and electron beams by Monte Carlo simulation. P_<repl> was calculated for cavities with a combination of various diameters and lengths. P_<repl> values calculated in photon and electron beams were typically higher than those recommended by the TG-51 and TRS-398 dosimetry protocols. P_<repl> values for a Farmer chamber cavity were higher by 0.3 to 0.2% and by 0.7 to 0.4%, respectively, than data of TG-51 and TRS-398, at photon energies of ^<60>Co to 18 MV. Similarly, the P_<repl> values for electron beams were higher by 1.5 to 1.1% than data for both protocols, in a range of 6-18 MeV. The P_<repl> values depended upon the cavity diameter and length, especially for lower electron energies. We found that P_<repl> values of cylindrical chamber cavities for photon and electron beams were significantly different from those recommended by TG-51 and TRS-398. | |||||
書誌情報 |
Radiological Physics and Technology 巻 5, 号 2, p. 199-206, 発行年 2012-07 |
|||||
ISSN | ||||||
収録物識別子 | 18650333 | |||||
書誌レコードID | ||||||
収録物識別子 | AA12236881 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
関連識別子 | 10.1007/s12194-012-0154-5 | |||||
フォーマット | ||||||
内容記述 | application/pdf | |||||
形態 | ||||||
323921 bytes | ||||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
日本十進分類法 | ||||||
主題 | 492.8 | |||||
出版者 | ||||||
出版者 | Springer Japan | |||||
資源タイプ | ||||||
内容記述 | 論文(Article) | |||||
資源タイプ・ローカル | ||||||
雑誌掲載論文 | ||||||
資源タイプ・NII | ||||||
Journal Article | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
01 | ||||||
URL | ||||||
内容記述 | http://link.springer.com/article/10.1007%2Fs12194-012-0154-5 | |||||
コメント | ||||||
The final publication is available at Springer via http://dx.doi.org/10.1007/s12194-012-0154-5 | ||||||
コメント | ||||||
【著者所属】 熊本大学大学院生命科学研究部 医用画像学 |