{"created":"2023-06-19T09:11:16.168223+00:00","id":22944,"links":{},"metadata":{"_buckets":{"deposit":"c7dbc60e-be80-4cca-a76c-3804cd34e146"},"_deposit":{"created_by":1,"id":"22944","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"22944"},"status":"published"},"_oai":{"id":"oai:kumadai.repo.nii.ac.jp:00022944","sets":["426:428"]},"author_link":["99857","147499","99862","99864","99858","99863"],"item_16_alternative_title_22":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A gas compressor using magnetic fluid : 5th report, Improvement in magnetic fluid-air introduction system"}]},"item_16_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"ジセイリュウタイ ヲ リヨウ シタ ガス カッシュクキ ダイ5ホウ ジセイリュウタイ キュウキ ドウニュウブ ノ カイリョウ"}]},"item_16_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-09-04","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"490","bibliographicPageStart":"489","bibliographic_titles":[{"bibliographic_title":"年次大会講演論文集 : JSME annual meeting 2004(2)"}]}]},"item_16_creator_3":{"attribute_name":"別言語の著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sadatomi, Michio"}],"nameIdentifiers":[{"nameIdentifier":"99862","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ii, Hideki"}],"nameIdentifiers":[{"nameIdentifier":"99863","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yokokawa, Kensaku"}],"nameIdentifiers":[{"nameIdentifier":"99864","nameIdentifierScheme":"WEKO"}]}]},"item_16_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_16_description_46":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_16_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"In order to improve the performance of the gas compressor using magnetic fluid, which was developed originally by Sato and Sadatomi (1993), an introduction system of the magnetic fluid and air have been changed and tested. As a result of the test, the discharge pressure and the discharge rate of the revised compressor remarkably increased from the former one. In the present paper, the modified introduction system and the test results are briefly described.","subitem_description_type":"Other"}]},"item_16_description_77":{"attribute_name":"URL","attribute_value_mlt":[{"subitem_description":"http://ci.nii.ac.jp/naid/110004062653@@@http://www.jsme.or.jp/","subitem_description_type":"Other"}]},"item_16_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人 日本機械学会"}]},"item_16_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人 日本機械学会"}]},"item_16_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11461871","subitem_source_identifier_type":"NCID"}]},"item_16_subject_20":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"530","subitem_subject_scheme":"NDC"}]},"item_16_text_18":{"attribute_name":"形態","attribute_value_mlt":[{"subitem_text_value":"247503 bytes"}]},"item_16_text_37":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ニホン キカイ ガッカイ"}]},"item_16_text_38":{"attribute_name":"別言語の出版者","attribute_value_mlt":[{"subitem_text_value":"The Japan Society of Mechanical Engineers"}]},"item_16_text_47":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"雑誌掲載論文"}]},"item_16_text_48":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Journal Article"}]},"item_16_text_49":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_16_text_50":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"01"}]},"item_16_text_78":{"attribute_name":"コメント","attribute_value_mlt":[{"subitem_text_value":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_16_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"佐田富, 道雄","creatorNameLang":"ja"},{"creatorName":"Sadatomi, Michio","creatorNameLang":"en"},{"creatorName":"サダトミ, ミチオ","creatorNameLang":"ja-Kana"}],"familyNames":[{"familyName":"佐田富","familyNameLang":"ja"},{"familyName":"Sadatomi","familyNameLang":"en"},{"familyName":"サダトミ","familyNameLang":"ja-Kana"}],"givenNames":[{"givenName":"道雄","givenNameLang":"ja"},{"givenName":"Michio","givenNameLang":"en"},{"givenName":"ミチオ","givenNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"147499","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井伊, 秀樹"}],"nameIdentifiers":[{"nameIdentifier":"99857","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"横川, 健作"}],"nameIdentifiers":[{"nameIdentifier":"99858","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-03-02"}],"displaytype":"detail","filename":"110004062653.pdf","filesize":[{"value":"247.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110004062653.pdf","url":"https://kumadai.repo.nii.ac.jp/record/22944/files/110004062653.pdf"},"version_id":"8e458c38-0a4f-433c-9f41-7b6aa811b7fc"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Gas compressor","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic fluid","subitem_subject_scheme":"Other"},{"subitem_subject":"Traveling magnetism","subitem_subject_scheme":"Other"},{"subitem_subject":"Discharge pressure","subitem_subject_scheme":"Other"},{"subitem_subject":"Discharge rate","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"磁性流体を利用したガス圧縮機 : 第5報,磁性流体-空気導入部の改良","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"磁性流体を利用したガス圧縮機 : 第5報,磁性流体-空気導入部の改良"}]},"item_type_id":"16","owner":"1","path":["428"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-10-27"},"publish_date":"2009-10-27","publish_status":"0","recid":"22944","relation_version_is_last":true,"title":["磁性流体を利用したガス圧縮機 : 第5報,磁性流体-空気導入部の改良"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-08-10T06:37:29.694119+00:00"}