ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 工学
  2. 発表論文(工学系)

Gold single-crystal electrode surface modified with self-assembled monolayers for electron tunneling with bilirubin oxidase

http://hdl.handle.net/2298/16669
http://hdl.handle.net/2298/16669
563b1a27-d20c-4f5e-9d60-41d01013a1cc
名前 / ファイル ライセンス アクション
2008PCCP_tominaga.pdf 2008PCCP_tominaga.pdf (2.3 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-11-01
タイトル
タイトル Gold single-crystal electrode surface modified with self-assembled monolayers for electron tunneling with bilirubin oxidase
言語
言語 eng
キーワード
主題 Bilirubin oxidase, electron transfer, catalytic current, self-assembled monolayer, single crystal electrode
資源タイプ
資源タイプ journal article
著者 Tominaga, Masato

× Tominaga, Masato

WEKO 106721

Tominaga, Masato

Search repository
Ohtani, Mai

× Ohtani, Mai

WEKO 106722

Ohtani, Mai

Search repository
Taniguchi, Isao

× Taniguchi, Isao

WEKO 106723

Taniguchi, Isao

Search repository
別言語の著者 冨永, 昌人

× 冨永, 昌人

WEKO 106727

冨永, 昌人

Search repository
大谷, まい

× 大谷, まい

WEKO 106728

大谷, まい

Search repository
谷口, 功

× 谷口, 功

WEKO 106729

谷口, 功

Search repository
内容記述
内容記述 Using Au(111) and Au(100) single-crystal electrodes modified with self-assembled monolayers (SAMs), the direct electron transfer reaction of bilirubin oxidase (BOD) adsorbed onto their surfaces was investigated. The BOD adsorbed onto the Au(111), Au(100) and gold /mica electrodes, and the BOD adsorbed onto Au(111) electrodes modified with C3–SO3H and Cn–COOH (n = 2, 5 and 7), showed the electrocatalytic currents of dioxygen reduction based on the direct electron transfer reaction. The BOD adsorbed onto Au(111) electrodes modified with C6–NH2, C6–OH and C5–CH3 did not show any electrocatalytic current. Negatively charged electrode surfaces can give a suitable molecular orientation for the direct electron transfer of BOD. The k° values evaluated by an analysis of the steady-state voltammogram with a simulated fitting method did not depend on the crystal structure of the gold electrode surface. Using a Cn–COOH (n = 2, 5, 7) modified Au(111) electrode, the k° values decreased with an increasing alkyl chain length of Cn–COOH. Based on the k° values obtained from the Cn–COOH (n = 2, 5, 7) modified Au(111) electrodes, the electron tunneling distance was evaluated. The average distance between the type 1 Cu site of BOD and the outside of the BOD protein structure was evaluated to be 17 (±2) Å.
書誌情報 Physical Chemistry Chemical Physics

巻 10, 号 46, p. 6928-6934, 発行年 2008-12-14
DOI
関連タイプ isVersionOf
関連識別子 10.1039/b809737b
情報源(ISSN)
関連名称 14639076
フォーマット
内容記述タイプ Other
内容記述 application/pdf
形態
2274448 bytes
著者版フラグ
出版タイプ AM
日本十進分類法
主題Scheme NDC
主題 431
出版者
出版者 Royal Society of Chemistry
資源タイプ
内容記述タイプ Other
内容記述 論文(Article)
資源タイプ・ローカル
雑誌掲載論文
資源タイプ・NII
Journal Article
資源タイプ・DCMI
text
資源タイプ・ローカル表示コード
01
URL
内容記述タイプ Other
内容記述 http://pubs.rsc.org/en/Content/ArticleLanding/2008/CP/b809737b
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 18:28:11.705539
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3