{"created":"2023-06-19T09:12:43.265728+00:00","id":24590,"links":{},"metadata":{"_buckets":{"deposit":"60c9309f-ef45-4b9d-af05-d45160d6e3ca"},"_deposit":{"created_by":1,"id":"24590","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"24590"},"status":"published"},"_oai":{"id":"oai:kumadai.repo.nii.ac.jp:00024590","sets":["448:449"]},"author_link":["146928"],"item_16_alternative_title_22":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Development of Miniature Key Devices for Flow Analysis and Their Applications"}]},"item_16_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"フロー ブンセキ ニ オケル コガタ キー デバイス ノ カイハツ ト オウヨウ"}]},"item_16_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"219","bibliographicPageStart":"207","bibliographicVolumeNumber":"53","bibliographic_titles":[{"bibliographic_title":"Bunseki Kagaku"}]}]},"item_16_creator_3":{"attribute_name":"別言語の著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"戸田, 敬","creatorNameLang":"ja"},{"creatorName":"トダ, ケイ","creatorNameLang":"ja-Kana"},{"creatorName":"Toda, Kei","creatorNameLang":"en"}],"familyNames":[{"familyName":"戸田","familyNameLang":"ja"},{"familyName":"トダ","familyNameLang":"ja-Kana"},{"familyName":"Toda","familyNameLang":"en"}],"givenNames":[{"givenName":"敬","givenNameLang":"ja"},{"givenName":"ケイ","givenNameLang":"ja-Kana"},{"givenName":"Kei","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"146928","nameIdentifierScheme":"WEKO"}]}]},"item_16_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf|application/pdf","subitem_description_type":"Other"}]},"item_16_description_46":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_16_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Micro or miniature devices have been developed for flow analysis to obtain excellent\nperformance. Some kinds of devices that we have developed are discussed in this paper.\nOne of the advantages of miniaturization is a small reagent consumption and a field\naffordable size for “environmentally-friendly environmental analysis”. The miniature\ndevice is better for not only the operational usefulness, but also for the performance\nof the instrument. For example, a perfect collection efficiency is obtained in an\nelectrochemical detection system microfabricated in a thin-layered wall-jet cell,\nand incubation is not needed in an enzyme-immobilized capillary cell. A small heat\ncapacity is necessary for thermal detection, and a high-performance thermal sensor for\nflow enthalpimetry has been developed using a small stainless steel capillary. A gas\n diffusion scrubber has also been miniaturized so as to be placed into a flow system.\nThe small diffusion scrubber has a large surface-to-volume ratio so that the sample gas\nis highly accumulated into the absorbing solution. The solution volume of the diffusion\nscrubber is same as that of the sample loop of FIA-sample-injector, and the scrubber\nis suited for being combined with the conventional flow injection system. Near real-time\nmeasurements of atmospheric gases have been conducted with miniature gas diffusion\nscrubbers and flow injection systems. In addition, novel collection/detection cells were\ndeveloped for measuring atmospheric gases in-situ in a cell using the stopped-flow method.","subitem_description_type":"Other"}]},"item_16_description_77":{"attribute_name":"URL","attribute_value_mlt":[{"subitem_description":"http://www.jstage.jst.go.jp/article/bunsekikagaku/53/4/53_207/_article","subitem_description_type":"Other"}]},"item_16_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society for Analytical Chemistry"}]},"item_16_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2116/bunsekikagaku.53.207","subitem_relation_type_select":"DOI"}}]},"item_16_relation_16":{"attribute_name":"情報源(ISSN)","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"0525-1931"}]}]},"item_16_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©2004 The Japan Society for Analytical Chemistry"}]},"item_16_subject_20":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"433","subitem_subject_scheme":"NDC"}]},"item_16_text_18":{"attribute_name":"形態","attribute_value_mlt":[{"subitem_text_value":"1010628 bytes|58228 bytes"}]},"item_16_text_47":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"雑誌掲載論文"}]},"item_16_text_48":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Journal Article"}]},"item_16_text_49":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_16_text_50":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"01"}]},"item_16_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"戸田, 敬","creatorNameLang":"ja"},{"creatorName":"トダ, ケイ","creatorNameLang":"ja-Kana"},{"creatorName":"Toda, Kei","creatorNameLang":"en"}],"familyNames":[{"familyName":"戸田","familyNameLang":"ja"},{"familyName":"トダ","familyNameLang":"ja-Kana"},{"familyName":"Toda","familyNameLang":"en"}],"givenNames":[{"givenName":"敬","givenNameLang":"ja"},{"givenName":"ケイ","givenNameLang":"ja-Kana"},{"givenName":"Kei","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"146928","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-03-02"}],"displaytype":"detail","filename":"BK53_4_207-219.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"BK53_4_207-219.pdf","url":"https://kumadai.repo.nii.ac.jp/record/24590/files/BK53_4_207-219.pdf"},"version_id":"e7b2cacb-7e4c-4153-8237-e4533cde8a58"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"miniature device","subitem_subject_scheme":"Other"},{"subitem_subject":"flow injection analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"electrochemical and thermal detection","subitem_subject_scheme":"Other"},{"subitem_subject":"atmospheric gas measurement","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"フロー分析における小型キーデバイスの開発と応用","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"フロー分析における小型キーデバイスの開発と応用"}]},"item_type_id":"16","owner":"1","path":["449"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-03-07"},"publish_date":"2011-03-07","publish_status":"0","recid":"24590","relation_version_is_last":true,"title":["フロー分析における小型キーデバイスの開発と応用"],"weko_creator_id":"1","weko_shared_id":1},"updated":"2023-09-26T02:33:20.148119+00:00"}