{"created":"2023-06-19T09:12:52.342885+00:00","id":24783,"links":{},"metadata":{"_buckets":{"deposit":"91cfa2d3-5c09-4cb8-bd38-24f2b8d2ad54"},"_deposit":{"created_by":1,"id":"24783","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"24783"},"status":"published"},"_oai":{"id":"oai:kumadai.repo.nii.ac.jp:00024783","sets":["413:429"]},"author_link":["147584","111404"],"item_18_alternative_title_22":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The research of the measurement accuracyof the vascular imaging in the different magnetic field strength MR Units"}]},"item_18_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"ジバ キョウド ガ コトナル MR ソウチ デノ ケッカン サツゾウ ノ ソクテイ セイド ノ ケンキュウ"}]},"item_18_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-05-28","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{}]}]},"item_18_creator_3":{"attribute_name":"別言語の著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"肥合, 康弘","creatorNameLang":"ja"},{"creatorName":"ヒアイ, ヤスヒロ","creatorNameLang":"ja-Kana"},{"creatorName":"Hiai, Yasuhiro","creatorNameLang":"en"}],"familyNames":[{"familyName":"肥合","familyNameLang":"ja"},{"familyName":"ヒアイ","familyNameLang":"ja-Kana"},{"familyName":"Hiai","familyNameLang":"en"}],"givenNames":[{"givenName":"康弘","givenNameLang":"ja"},{"givenName":"ヤスヒロ","givenNameLang":"ja-Kana"},{"givenName":"Yasuhiro","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"147584","nameIdentifierScheme":"WEKO"}]}]},"item_18_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf"}]},"item_18_description_46":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"研究報告書","subitem_description_type":"Other"}]},"item_18_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"3Tという強い磁場強度を持つMR装置が臨床に用いられる様になり、MR血管撮像の画質が大きく変化した。本研究は、それにより動脈瘤及び狭窄性病変の描出能がどのように変化したかを比較検討した。それと同時に、高磁場における撮像条件の最適化を行った。高い磁場により増加したSNRを、マトリックス数を増加させることによる高分解化に利用する事で、評価を向上させる事ができる。また、最適化した撮像条件において視覚評価及び定量評価両面において、画質が向上している事が確認出来た。","subitem_description_type":"Other"}]},"item_18_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"熊本大学"}]},"item_18_subject_20":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"492.1","subitem_subject_scheme":"NDC"}]},"item_18_text_18":{"attribute_name":"形態","attribute_value_mlt":[{"subitem_text_value":"221020 bytes"}]},"item_18_text_47":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"研究報告書"}]},"item_18_text_48":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Research Paper"}]},"item_18_text_49":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_18_text_50":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"06"}]},"item_18_text_78":{"attribute_name":"コメント","attribute_value_mlt":[{"subitem_text_value":"平成19~20年度科学研究費補助金(基盤研究(C))研究成果報告書 課題番号:19591426"}]},"item_18_text_80":{"attribute_name":"科研費番号","attribute_value_mlt":[{"subitem_text_value":"19591426"}]},"item_18_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"肥合, 康弘"}],"nameIdentifiers":[{"nameIdentifier":"111404","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-03-02"}],"displaytype":"detail","filename":"KaC19591426.pdf","filesize":[{"value":"221.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KaC19591426.pdf","url":"https://kumadai.repo.nii.ac.jp/record/24783/files/KaC19591426.pdf"},"version_id":"06fd4f0b-54fe-4956-9018-666dbabe4403"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"MRI","subitem_subject_scheme":"Other"},{"subitem_subject":"MRA","subitem_subject_scheme":"Other"},{"subitem_subject":"動脈瘤","subitem_subject_scheme":"Other"},{"subitem_subject":"血管狭窄","subitem_subject_scheme":"Other"},{"subitem_subject":"3Tesla","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"磁場強度が異なるMR装置での血管撮像の測定精度の研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"磁場強度が異なるMR装置での血管撮像の測定精度の研究"}]},"item_type_id":"18","owner":"1","path":["429"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-06-10"},"publish_date":"2011-06-10","publish_status":"0","recid":"24783","relation_version_is_last":true,"title":["磁場強度が異なるMR装置での血管撮像の測定精度の研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-09-14T07:29:20.668291+00:00"}