WEKO3
アイテム
Emergency Control of Power Systems in Steady and Dynamical State
http://hdl.handle.net/2298/21584
http://hdl.handle.net/2298/2158419d37557-08b7-4f5f-a15a-d4937c1b16ed
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-09-30 | |||||
タイトル | ||||||
タイトル | Emergency Control of Power Systems in Steady and Dynamical State | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題 | Power of system, Emergency Control, Blackout, Training | |||||
資源タイプ | ||||||
資源タイプ | thesis | |||||
著者 |
Anuar, Bin Mohamad
× Anuar, Bin Mohamad |
|||||
別言語の著者 |
アニュアル, ビン モハマド
× アニュアル, ビン モハマド |
|||||
内容記述 | ||||||
内容記述 | Preparation and training of emergency control in power system is one of the important in minimizing the impact of wide spread system disturbance. Impact of wide spread system disturbance can cause partial or complete blackout. Furthermore blackout events can affect to huge economic costs and may even lead to loss of life. Control in an emergency state involves special facilities and procedures provided by a utility. It is to maintain and restore viable operation, following an incident. Controlled separation is one of the control solutions in emergency control. This thesis shows preparation and training under steady state and dynamic condition for controlled separation. The benefit of steady state is to study feasible splitting strategies and optimal placement of Phase Measurement Units. Practically, each region has different power generation, load demand and reserve capacity. This situation creates effectiveness in the dynamics of real-time by using rate of frequency and regional coordination in sub-areas. The reserve margin is then used to identify a sequential load shedding. This research has revealed tracing power between generation and load for is landed operation to be useful for feasible splitting strategies and optimal placement of Phase Measurement Units. Also, the amount of load shedding over the sub-areas with respect to reserve margin will be a practical value in deregulated environments. Due to effective controlled separation, the system can be stabilized faster with less amount of load to be shed than the uncontrolled separation case. | |||||
書誌情報 | 発行年 2011-03-25 | |||||
フォーマット | ||||||
内容記述 | application/pdf | |||||
形態 | ||||||
1972230 bytes | ||||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
日本十進分類法 | ||||||
主題 | 377.5 | |||||
その他の言語のタイトル | ||||||
その他のタイトル | 定態および動態状態における電力システムの緊急制御 | |||||
タイトル(ヨミ) | ||||||
その他のタイトル | テイタイ オヨビ ドウタイ ジョウタイ ニ オケル デンリョク システム ノ キンキュウ セイギョ | |||||
出版者 | ||||||
出版者 | 熊本大学 | |||||
資源タイプ | ||||||
内容記述 | 学位論文(Thesis) | |||||
資源タイプ・ローカル | ||||||
博士論文 | ||||||
資源タイプ・NII | ||||||
Thesis or Dissertation | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
03 | ||||||
コメント | ||||||
熊本大学大学院自然科学研究科 情報電気電子工学専攻 | ||||||
学位番号 | ||||||
甲博学第224号 |