WEKO3
アイテム
{"_buckets": {"deposit": "f6af26b4-2070-4708-9b97-1f7ff0e61eea"}, "_deposit": {"created_by": 1, "id": "24829", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "24829"}, "status": "published"}, "_oai": {"id": "oai:kumadai.repo.nii.ac.jp:00024829", "sets": ["443"]}, "author_link": ["111729", "111733", "134261", "111728"], "item_16_alternative_title_22": {"attribute_name": "その他の言語のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "LUNG DOSE CORRECTIONS FOR 10 MV X-RAYS FROM A LINEAR ACCELERATOR"}]}, "item_16_alternative_title_23": {"attribute_name": "タイトル(ヨミ)", "attribute_value_mlt": [{"subitem_alternative_title": "リニアック 10MVXセン ニ オケル ハイ ノ センリョウ ホセイ"}]}, "item_16_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1993-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "38", "bibliographicPageStart": "32", "bibliographicVolumeNumber": "49", "bibliographic_titles": [{"bibliographic_title": "日本放射線技術學會雜誌"}]}]}, "item_16_creator_3": {"attribute_name": "別言語の著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "荒木, 不次男", "creatorNameLang": "ja"}, {"creatorName": "アラキ, フジオ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Araki, Fujio", "creatorNameLang": "en"}], "familyNames": [{"familyName": "荒木", "familyNameLang": "ja"}, {"familyName": "アラキ", "familyNameLang": "ja-Kana"}, {"familyName": "Araki", "familyNameLang": "en"}], "givenNames": [{"givenName": "不次男", "givenNameLang": "ja"}, {"givenName": "フジオ", "givenNameLang": "ja-Kana"}, {"givenName": "Fujio", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "134261", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kumagai, Kozo"}], "nameIdentifiers": [{"nameIdentifier": "111733", "nameIdentifierScheme": "WEKO"}]}]}, "item_16_description_17": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_16_description_46": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_16_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "In radiation therapy of thorax region, it is necessary to apply absorbed dose correction for heterogeneity tissuse of lungs. Practically, however, it is not easy to do an accurate absorbed dose correction. We made a basic experiment for absorbed dose correction of heterogeneity tissue of lungs using thorax phantom for 10 MV X-rays, and evaluated the accuracy of depth dose calculation algorithms for its tissue which are available in conventional, commercial-based treatment-planning systems. Depth dose on the central axis in lung for small field of 5×5(cm)^2 was reduced by about 10% due to loss of lateral electronic equilibrium. Dose correction factor of heterogeneity was insensitive to the thickness of the build-up layer of this phantom if there was a longitudinal electronic equilibrium. The equivalent TAR (tissue-air ratio) method gave the greatest accuracy for dose calculation algorithms, of lungs whose error was within about 3% compared to the measured values. However, for the smaller field of 5×5(cm)^2, all our methods did not consider the effects of electron scattering, so that the equivalent TAR method and the ratio of TAR method gave errors of about 15% and the power law TAR method about 6%.", "subitem_description_type": "Other"}]}, "item_16_description_77": {"attribute_name": "URL", "attribute_value_mlt": [{"subitem_description": "http://ci.nii.ac.jp/naid/110003465509", "subitem_description_type": "Other"}]}, "item_16_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "公益社団法人日本放射線技術学会"}]}, "item_16_relation_16": {"attribute_name": "情報源(ISSN)", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "03694305"}]}]}, "item_16_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "公益社団法人日本放射線技術学会"}]}, "item_16_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00197784", "subitem_source_identifier_type": "NCID"}]}, "item_16_subject_20": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "492.4", "subitem_subject_scheme": "NDC"}]}, "item_16_text_18": {"attribute_name": "形態", "attribute_value_mlt": [{"subitem_text_value": "493159 bytes"}]}, "item_16_text_47": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "雑誌掲載論文"}]}, "item_16_text_48": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Journal Article"}]}, "item_16_text_49": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_16_text_50": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "01"}]}, "item_16_text_76": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/2298/19779"}]}, "item_16_text_78": {"attribute_name": "コメント", "attribute_value_mlt": [{"subitem_text_value": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}, {"subitem_text_value": "荒木不次男\n現:熊本大学医学部保健学科教授(医用画像学)"}]}, "item_16_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "荒木, 不次男"}], "nameIdentifiers": [{"nameIdentifier": "111728", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "熊谷, 孝三"}], "nameIdentifiers": [{"nameIdentifier": "111729", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-03-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "110003465509.pdf", "filesize": [{"value": "493.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 493200.0, "url": {"label": "110003465509.pdf", "url": "https://kumadai.repo.nii.ac.jp/record/24829/files/110003465509.pdf"}, "version_id": "94563652-88ae-41ae-980b-68f56034ee8b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Lung correction factor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Dose alculation algorithms", "subitem_subject_scheme": "Other"}, {"subitem_subject": "10 MV X-rays", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Electronic equilibrium", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "リニアック 10 MV X 線における肺の線量補正", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "リニアック 10 MV X 線における肺の線量補正"}]}, "item_type_id": "16", "owner": "1", "path": ["443"], "permalink_uri": "http://hdl.handle.net/2298/19779", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-06-22"}, "publish_date": "2011-06-22", "publish_status": "0", "recid": "24829", "relation": {}, "relation_version_is_last": true, "title": ["リニアック 10 MV X 線における肺の線量補正"], "weko_shared_id": -1}
リニアック 10 MV X 線における肺の線量補正
http://hdl.handle.net/2298/19779
http://hdl.handle.net/2298/197794c19f0d0-f501-4aea-acbe-05796b5c0c7c
名前 / ファイル | ライセンス | アクション |
---|---|---|
110003465509.pdf (493.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-06-22 | |||||
タイトル | ||||||
タイトル | リニアック 10 MV X 線における肺の線量補正 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | Lung correction factor, Dose alculation algorithms, 10 MV X-rays, Electronic equilibrium | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
著者 |
荒木, 不次男
× 荒木, 不次男× 熊谷, 孝三 |
|||||
別言語の著者 |
荒木, 不次男
× 荒木, 不次男× Kumagai, Kozo |
|||||
内容記述 | ||||||
内容記述 | In radiation therapy of thorax region, it is necessary to apply absorbed dose correction for heterogeneity tissuse of lungs. Practically, however, it is not easy to do an accurate absorbed dose correction. We made a basic experiment for absorbed dose correction of heterogeneity tissue of lungs using thorax phantom for 10 MV X-rays, and evaluated the accuracy of depth dose calculation algorithms for its tissue which are available in conventional, commercial-based treatment-planning systems. Depth dose on the central axis in lung for small field of 5×5(cm)^2 was reduced by about 10% due to loss of lateral electronic equilibrium. Dose correction factor of heterogeneity was insensitive to the thickness of the build-up layer of this phantom if there was a longitudinal electronic equilibrium. The equivalent TAR (tissue-air ratio) method gave the greatest accuracy for dose calculation algorithms, of lungs whose error was within about 3% compared to the measured values. However, for the smaller field of 5×5(cm)^2, all our methods did not consider the effects of electron scattering, so that the equivalent TAR method and the ratio of TAR method gave errors of about 15% and the power law TAR method about 6%. | |||||
書誌情報 |
日本放射線技術學會雜誌 巻 49, 号 1, p. 32-38, 発行年 1993-01-01 |
|||||
書誌レコードID | ||||||
収録物識別子 | AN00197784 | |||||
権利 | ||||||
権利情報 | 公益社団法人日本放射線技術学会 | |||||
情報源(ISSN) | ||||||
関連名称 | 03694305 | |||||
フォーマット | ||||||
内容記述 | application/pdf | |||||
形態 | ||||||
493159 bytes | ||||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
日本十進分類法 | ||||||
主題 | 492.4 | |||||
その他の言語のタイトル | ||||||
その他のタイトル | LUNG DOSE CORRECTIONS FOR 10 MV X-RAYS FROM A LINEAR ACCELERATOR | |||||
タイトル(ヨミ) | ||||||
その他のタイトル | リニアック 10MVXセン ニ オケル ハイ ノ センリョウ ホセイ | |||||
出版者 | ||||||
出版者 | 公益社団法人日本放射線技術学会 | |||||
資源タイプ | ||||||
内容記述 | 論文(Article) | |||||
資源タイプ・ローカル | ||||||
雑誌掲載論文 | ||||||
資源タイプ・NII | ||||||
Journal Article | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
01 | ||||||
URL | ||||||
内容記述 | http://ci.nii.ac.jp/naid/110003465509 | |||||
コメント | ||||||
本文データは学協会の許諾に基づきCiNiiから複製したものである | ||||||
コメント | ||||||
荒木不次男 現:熊本大学医学部保健学科教授(医用画像学) |