{"_buckets": {"deposit": "d6600519-d10c-478e-90e6-ca25fae43de7"}, "_deposit": {"created_by": 1, "id": "23848", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "23848"}, "status": "published"}, "_oai": {"id": "oai:kumadai.repo.nii.ac.jp:00023848", "sets": ["349"]}, "author_link": ["104907", "147584"], "item_14_alternative_title_22": {"attribute_name": "その他の言語のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "3T MR血管撮影による脳動脈瘤診断の基礎的検討"}]}, "item_14_alternative_title_23": {"attribute_name": "タイトル(ヨミ)", "attribute_value_mlt": [{"subitem_alternative_title": "3T MR ケッカン サツエイ ニヨル ノウ ドウミャクリュウ シンダン ノ キソテキ ケントウ"}]}, "item_14_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-03-25", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}]}]}, "item_14_creator_3": {"attribute_name": "別言語の著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "肥合, 康弘", "creatorNameLang": "ja"}, {"creatorName": "ヒアイ, ヤスヒロ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Hiai, Yasuhiro", "creatorNameLang": "en"}], "familyNames": [{"familyName": "肥合", "familyNameLang": "ja"}, {"familyName": "ヒアイ", "familyNameLang": "ja-Kana"}, {"familyName": "Hiai", "familyNameLang": "en"}], "givenNames": [{"givenName": "康弘", "givenNameLang": "ja"}, {"givenName": "ヤスヒロ", "givenNameLang": "ja-Kana"}, {"givenName": "Yasuhiro", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "147584", "nameIdentifierScheme": "WEKO"}]}]}, "item_14_description_17": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_14_description_46": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "学位論文(Thesis)", "subitem_description_type": "Other"}]}, "item_14_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "The purpose of this study were two folds: (1) to analyze the influence of matrix, parallel imaging and acquisition time on image quality of 3D TOF MRA at 1.5T and 3T, and to illustrate whether the combination of larger matrices with parallel imaging technique is feasible, by evaluating the visualization of simulated intracranial aneurysms and aneurysmal blebs using a vascular phantom with pulsatile flow; and (2) to analyze the influence of the matrix and the echo time (TE) of 3D TOF MRA on the depiction of residual flow in aneurysms embolized with platinum coils at 1.5T and 3T and to establish the optimal parameters using a vascular phantom with a pulsatile flow.", "subitem_description_type": "Other"}]}, "item_14_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "熊本大学"}]}, "item_14_subject_20": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "493.24", "subitem_subject_scheme": "NDC"}]}, "item_14_text_18": {"attribute_name": "形態", "attribute_value_mlt": [{"subitem_text_value": "7504367 bytes"}]}, "item_14_text_47": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "博士論文"}]}, "item_14_text_48": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Thesis or Dissertation"}]}, "item_14_text_49": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_14_text_50": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "03"}]}, "item_14_text_76": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/2298/15753"}]}, "item_14_text_78": {"attribute_name": "コメント", "attribute_value_mlt": [{"subitem_text_value": "熊本大学大学院医学教育部 病態制御学専攻"}]}, "item_14_text_81": {"attribute_name": "学位番号", "attribute_value_mlt": [{"subitem_text_value": "甲博医第1650号"}]}, "item_14_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "肥合, 康弘"}], "nameIdentifiers": [{"nameIdentifier": "104907", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-03-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "22-1650.pdf", "filesize": [{"value": "7.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 7500000.0, "url": {"label": "22-1650.pdf", "url": "https://kumadai.repo.nii.ac.jp/record/23848/files/22-1650.pdf"}, "version_id": "7fcf87c8-a2ec-486e-af4c-8b7523b9a362"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "thesis", "resourceuri": "http://purl.org/coar/resource_type/c_46ec"}]}, "item_title": "A fundamental study in the diagnosis of intracranial aneurysms with 3T MR angiography", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A fundamental study in the diagnosis of intracranial aneurysms with 3T MR angiography"}]}, "item_type_id": "14", "owner": "1", "path": ["349"], "permalink_uri": "http://hdl.handle.net/2298/15753", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-08-17"}, "publish_date": "2010-08-17", "publish_status": "0", "recid": "23848", "relation": {}, "relation_version_is_last": true, "title": ["A fundamental study in the diagnosis of intracranial aneurysms with 3T MR angiography"], "weko_shared_id": -1}
A fundamental study in the diagnosis of intracranial aneurysms with 3T MR angiography
http://hdl.handle.net/2298/15753
http://hdl.handle.net/2298/157537df13cb2-97f0-402b-a265-dc7e7a8f10db
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-08-17 | |||||
タイトル | ||||||
タイトル | A fundamental study in the diagnosis of intracranial aneurysms with 3T MR angiography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ | thesis | |||||
著者 |
肥合, 康弘
× 肥合, 康弘 |
|||||
別言語の著者 |
肥合, 康弘
× 肥合, 康弘 |
|||||
内容記述 | ||||||
内容記述 | The purpose of this study were two folds: (1) to analyze the influence of matrix, parallel imaging and acquisition time on image quality of 3D TOF MRA at 1.5T and 3T, and to illustrate whether the combination of larger matrices with parallel imaging technique is feasible, by evaluating the visualization of simulated intracranial aneurysms and aneurysmal blebs using a vascular phantom with pulsatile flow; and (2) to analyze the influence of the matrix and the echo time (TE) of 3D TOF MRA on the depiction of residual flow in aneurysms embolized with platinum coils at 1.5T and 3T and to establish the optimal parameters using a vascular phantom with a pulsatile flow. | |||||
書誌情報 | 発行年 2008-03-25 | |||||
フォーマット | ||||||
内容記述 | application/pdf | |||||
形態 | ||||||
7504367 bytes | ||||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
日本十進分類法 | ||||||
主題 | 493.24 | |||||
その他の言語のタイトル | ||||||
その他のタイトル | 3T MR血管撮影による脳動脈瘤診断の基礎的検討 | |||||
タイトル(ヨミ) | ||||||
その他のタイトル | 3T MR ケッカン サツエイ ニヨル ノウ ドウミャクリュウ シンダン ノ キソテキ ケントウ | |||||
出版者 | ||||||
出版者 | 熊本大学 | |||||
資源タイプ | ||||||
内容記述 | 学位論文(Thesis) | |||||
資源タイプ・ローカル | ||||||
博士論文 | ||||||
資源タイプ・NII | ||||||
Thesis or Dissertation | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
03 | ||||||
コメント | ||||||
熊本大学大学院医学教育部 病態制御学専攻 | ||||||
学位番号 | ||||||
甲博医第1650号 |