WEKO3
アイテム
Detection of small pulmonary nodules on chest radiographs: efficacy of dual-energy subtraction technique using flat-panel detector chest radiography
http://hdl.handle.net/2298/19099
http://hdl.handle.net/2298/190990ecce3af-7596-4396-a794-a16f99965610
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-05-26 | |||||
タイトル | ||||||
タイトル | Detection of small pulmonary nodules on chest radiographs: efficacy of dual-energy subtraction technique using flat-panel detector chest radiography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
著者 |
Oda, Seitaro
× Oda, Seitaro× Awai, Kazuo× Funama, Yoshinori× 宇都宮, 大輔× Yanaga, Yumi× Kawanaka, Koichi× 中浦, 猛× Hirai, Toshinori× 村上, 龍次× Nomori, Hiroaki× 山下, 康行 |
|||||
別言語の著者 |
尾田, 済太郎
× 尾田, 済太郎× 粟井, 和夫× 船間, 芳憲× 宇都宮, 大輔× 彌永, 由美× 河中, 功一× 中浦, 猛× 平井, 俊範× 村上, 龍次× 野守, 裕明× 山下, 康行 |
|||||
内容記述 | ||||||
内容記述 | AIM:We investigated the effect of a double-exposure dual-energy subtraction (DES) technique on the performance of radiologists detecting small pulmonary nodules on flat-panel detector (FPD) chest radiographs. MATERIALS AND METHODS:Using FPD radiography we obtained 41 sets of chest radiographs from 26 patients with pulmonary nodules measuring ≤ 20 mm and from 15 normal subjects. Each data set included standard- and corresponding DES images. There were 6 non-solid-, 10 part-solid-, and 10 solid nodules. The mean size of the 26 nodules was 15.0 ± 4.8 mm. We performed receiver operating characteristic (ROC) analysis to compare the performance of 8 board-certified radiologists. RESULTS:For the 8 radiologists, the mean value of the area under the ROC curve (AUC) without and with DES images was 0.62 ± 0.05 and 0.68 ± 0.05, respectively; the difference was statistically significant (p = 0.02). For part-solid nodules, the difference of the mean AUC value was statistically significant (AUC = 0.61 ± 0.07 vs. 0.69 ± 0.05; p < 0.01); for non-solid nodules it was not (AUC = 0.62 ± 0.10 vs. 0.61 ± 0.09; p = 0.73), and for solid nodules it was not (AUC = 0.75 ± 0.10 vs. 0.78 ± 0.08; p = 0.23). For nodules with overlapping bone shadows, the difference of the mean AUC value was statistically significant (p = 0.03), for nodules without overlapping, it was not (p = 0.26). CONCLUSION:Use of a double-exposure DES technique at FPD chest radiography significantly improved the diagnostic performance of radiologists detecting small pulmonary nodules. |
|||||
書誌情報 |
Clinical Radiology 巻 65, 号 8, p. 609-615, 発行年 2010-08 |
|||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
関連識別子 | 10.1016/j.crad.2010.02.012 | |||||
情報源(ISSN) | ||||||
関連名称 | © 2010 The Royal College of Radiologists Published by Elsevier Ltd | |||||
情報源(ISSN) | ||||||
関連名称 | 00099260 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
形態 | ||||||
1058632 bytes | ||||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
日本十進分類法 | ||||||
主題Scheme | NDC | |||||
主題 | 492.4 | |||||
出版者 | ||||||
出版者 | The Royal College of Radiologists Published by Elsevier Ltd | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | 論文(Article) | |||||
資源タイプ・ローカル | ||||||
雑誌掲載論文 | ||||||
資源タイプ・NII | ||||||
Journal Article | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
01 | ||||||
URL | ||||||
内容記述タイプ | Other | |||||
内容記述 | http://www.sciencedirect.com/science/article/pii/S0009926010001170 |